Several ways of outputting current signal in the pipeline of V-cone flowmeter
Flow measurement is the most common measurement of fluid physical indicators in production and life. There are many principles for flow measurement. There are ultrasonic, electromagnetic, pressure, temperature and other measurement principles. Under normal circumstances, the flowmeter signal comes from flow, pressure, temperature detection. Components, reasonable selection of the installation position of different detection components can reduce the influence of fluid disturbance and noise, and improve the detection effect.
(1) Pressure detection
The most common such flowmeters are orifice flowmeters, annubar flowmeters, venturis, etc. by throttling devices.
The pressure detection of the fluid mostly uses a diffusion silicon pressure sensor or a ceramic pressure sensor. According to the principle of vortex precession, the position of the pressure tap should be selected in the throat of the measuring tube, because the pressure of the throat is the most representative of the pressure at which the nucleus precession zone is generated.
(2) vortex signal detection
The most common ones are rotary vortex flowmeters, turbine flowmeters, etc., and can use thermal, force sensitive, capacitive, ultrasonic, optical, electromagnetic and other detection components to detect local flow velocity changes caused by vortices and pressure pulsation of fluids to achieve vortex Signal Detection.
Reasonable selection of the mounting position of the detecting element has a good effect on obtaining a vortex signal with high intensity and low noise. After testing, the vortex signal detecting component is installed near the intersection of the throat and the expansion section of the measuring tube, and the vortex precession at this position is strong and the noise is small.
The detection method of the double detection component has better measurement effect. In the two measurements of the measuring tube, a pair of vortex signal detecting elements are symmetrically arranged. The two vortex signals have a phase difference of 180 degrees, and the differential detection method can obtain doubled signals, and can effectively eliminate common mode interference, such as pipeline vibration and flow field disturbance, thereby greatly improving the signal to noise ratio. Expand the flow measurement range.
The size of the sensing element should be as small as possible to reduce the disturbance of the sensing element to the flow field. If an insertion type detection element is used, the influence of the depth of the insertion element of the detection element should be considered. The detecting element has a large size and deep insertion, and the throttling effect is increased, and the disturbance to the flow field is also increased, which also affects the stability and frequency of the vortex core precession. Tests have shown that the insertion depth increases and the meter factor K of the flow meter increases, but the linearity of the flow meter deteriorates.
(3) Fluid temperature detection
Most of the fluid temperature detection uses platinum resistance detection components. The stability and reliability of the components are good, the price is not high, the volume is small, and the installation is convenient. In recent years, the thin film platinum resistance detecting element has a small volume and a fast response, and is a good temperature measuring element.
The position of the temperature measurement point should be selected in the outlet section of the measuring tube, where the temperature of the fluid is basically the same as that of the throat, and the temperature measuring element does not interfere with the precession of the vortex core.
Other Barware Items
Other Barware Items
There any many other kinds of barware items, Such as ice tong, wine cooler, ice shovel, cocktail shaker set and so on.
Welcome to provide the requirement or picture to ask for the quotation or recommend, will try to recommend the suitable one with excellent quality to you for reference.
Also can combine several items as one set ,such as the cocktail shaker set ,which including the shaker, spoon, bottom open, Measuring Cup and so on. Can satisfied with customers who want to enjoy it in home.
Will be glad to hear from you and have a good communication.
Material:SS304
Finishing: Satin polishing ,Mirror Polishing ,Color painting
Logo: Laser logo, Etching logo, Silk printing logo, Embossed logo, Decal logo
MOQ : 2000 PCS
Packaging : White box, Mail box or Customized package
Sample Time : 7~10 days
Lead Time :60 days after have the deposit
Payment: T/T ,L/C or others
Payment term: 30% deposit before production and 70 % balance against the copy B/L
FAQ:
1:How can I get the sample?
We can provide the sample for customers to check the quality.
Please kindly provide the delivery info for calculate the sample cost. If you have DHL /TNT/UPS/FEDEX account, please also kindly provide it to us.
You can do the payment of sample via T/T and PayPal.
2:How about the sample time?
Usually the sample time is 7~10 days after have the sample cost.
3:How long will it take for mass production?
Usually 45~60 days after have the deposit.
4:Can we have our logo or company name to be printed on your products or the package?
Welcome OEM.
5:what certificate can you provide?
CE,CB,GS,FDA,LFGB,ROHS are available here.
6:How can we get your monthly new products announcement?
Please join our mailing lists.
Our Service
Excellent quality
OEM packaging and product
Good service
Rich experience save your time and money