Level gauge installation precautions

1) The installation height of the buoyancy level gauge should meet the specifications of the design document.
2) The buoyancy level gauge shall be installed with the buoys in a vertical position at the level of the normal operation level or the boundary level of the buoy.
3) The duct of the steel belt level gauge should be installed vertically, and the steel belt should be in the center of the duct and slide freely.
4) When using a differential pressure gauge or differential pressure transmitter to measure the liquid level, the height of the instrument should not be higher than the lower pressure extraction port. (This method is not affected by the air blowing method and the low-boiling liquid vaporization pressure transmission method for measuring the liquid level. Regulations limit).
5) Double-flange differential pressure transmitter capillary should be laid with protective measures, the bending radius of not less than 50mm, when the surrounding temperature change is severe, heat insulation measures should be taken.
6) The load Sensor of the weighing level meter shall be installed and carried after the installation of the load-bearing container and all its components and connections.
7) -Generally measure the level of sewage, install the transmitter not to be installed at the bottom. The input type and pressure-conducting level gauge is put in from the top, leaving a certain distance from the bottom of the pool, more than 300mm is good, differential pressure / pressure / level transmitter installed in the side of the container, but also have a certain distance from the ground distance. 300mm can be.
8) Keep away from the pump, sewage pump and circulation pump when installing the level gauge. Avoid making the pool spray so that the measurement accuracy is not accurate.
9) In the industrial field, the moon float switch is usually used to control the start and stop of water and water. Although the float switch is cheap, the service life is very limited, and it is usually updated in one year or even several months. According to the author's on-site construction experience, the use of liquid level transmitters is relatively expensive, and it is generally desirable to use pressure transmitters, differential pressure transmitters, or pressure-conducting differential pressure transmitters and input level gauges. fair price.

Electrical System

Precautions for maintenance of electrical system of XCMG loader:

When repairing the electrical system of the machine, please strictly abide by the following items. Otherwise, a little carelessness may turn a small problem into a major accident and cause greater economic losses. When repairing, please cut off the power of the host before disconnecting the wires and connectors, otherwise it will cause damage to the wiring harness, fuse fuse, and sometimes even a fire caused by a short circuit of the wire. Correctly identify the wire mark of the wire. Each wire on the wire harness corresponds to a one- or two-digit wire mark. Please pay special attention to distinguish "3" from "8", "6" from "9", and "5" With "6", "0" and "8", "1" and "7" and other numbers, so as not to misunderstand and bring you unnecessary trouble.

SEM 50F, 650 electrical system,
Liugong loaders ZL50CN, 855N, 856 electrical system,
SDLG 956L 952H 953 electrical system,
XCMG electrical system LW500KL ZL50GN,
Komatsu WA380, WA380-3, WA380-5, WA430-5 electrical system
DEGONG loader electrical system
Foton Lovol Loader electrical system
Lonking 855N loader electrical system
XGMA 932 936 956 Loader electrical system
Changlin Loader electrical system

And we have more.

Electrical System,Wheel Loader Dashboard,Xgma Roller Coil Valve,Custom Electrical System

Shandong Tianfu International Trade Co.,Ltd. , https://www.tfloaderparts.com